- Home
- Services
- Public Works
- Engineering Division
- Standard Specifications & Detail Plates
Standard Specifications & Detail Plates
Below are the City of Lakeville's utility and street construction standard specifications and detail plates. For more information, contact the Engineering Department at 952-985-4500.
- Summary of 2024 Specification changes (PDF)
- City of Lakeville Right-of-Way Ordinance
- April 23, 2021: Section 3 of the City’s Standard Specifications have been updated to modify the Products for the Tracer Wire Specifications. The Non-Roadway access box has been modified from Part #LD14*TD to Part #LD14B2T-SW.
Utility & Street Construction Standard Specifications Book
Note: Specifications were changed as of February 2024.
- Section 1: Utility and Street Construction Plan Requirements (PDF)
- Section 2: Standard Specifications - Site Work (PDF)
- Section 3: Standard Specifications - Underground Construction (PDF)
- Section 4: Standard Specifications - Street Construction (PDF)
- Section 5: Standard Utilities Specifications (CEAM 2018)
- Section 6: Additional Specification Requirements for Developer-Installed Improvements (PDF)
- Section 7: Standard Symbols to Be Used on Utility and Street Construction Plans (PDF)
- Section 8: Standard Detail Plates (PDF)
- Section 9: Review and Approval of Plans and Specifications (PDF)
- Section 10: Construction Staking Requirements (PDF)
- Section 11: Procedures for Plan Revisions During Construction (PDF)
- Section 12: Procedures for Processing Partial Payment Requests (PDF)
- Section 13: Materials Testing Requirements (PDF)
- Section 14: Schedule of Required Utility Tests (PDF)
- Section 15: Schedule of Required Final Inspections (PDF)
- Section 16: Conditional Requirements for Building Service Connections (PDF)
- Section 17: Procedures for Letters of Credit Reduction (PDF)
- Section 18: Procedures for Final Acceptance of Utilities and Streets (PDF)
- Section 19: Construction Record Drawing Requirements (PDF)
Sanitary Sewer
| Sanitary Sewer | Plate Number |
|---|---|
| Standard Manhole (48" Inside Diameter) | LV-SS-1 (PDF) |
| Inside Drop Manhole (48" Inside Diameter) | LV-SS-2 (PDF) |
| Outside Drop Manhole (48" Inside Diameter) | LV-SS-3 (PDF) |
| Slab-Top Manhole | LV-SS-4 (PDF) |
| Air Release Manhole (Forcemain) | LV-SS-5 (PDF) |
| Typical House Service (4" or 6" Diameter Service) | LV-SS-6 (PDF) |
| Service Riser (Deep Lines) (4" or 6" Service) | LV-SS-7 (PDF) |
| Service Riser (Large Diameter Pipe) (4" or 6" Service) | LV-SS-8 (PDF) |
| Clean-Out Detail | LV-SS-9 (PDF) |
| Sanitary Sewer Manhole with Inside Service Drop | LV-SS-10 (PDF) |
| Non-Grinder Lift Station (Cross-Section View) | LV-SS-11A (PDF) |
| Non-Grinder Lift Station (Cross-Section Notes) | LV-SS-11B (PDF) |
| Non-Grinder Lift Station (Plan View) | LV-SS-12A (PDF) |
| Non-Grinder Lift Station (Plan View Notes) | LV-SS-12B (PDF) |
| Grinder Lift Station | LV-SS-13A (PDF) |
| Grinder Lift Station (Notes) | LV-SS-13B (PDF) |
| Standard Lift Station Details | LV-SS-14A (PDF) |
| Standard Lift Station Details | LV-SS-14B (PDF) |
| Lift Station Electrical Details | LV-SS-15A (PDF) |
| Lift Station Electrical Details | LV-SS-15B (PDF) |
| Watermain | Plate Number |
|---|---|
| Typical Water Layout | LV-WM-1 (PDF) |
| Typical Water Service Connection | LV-WM-2 (PDF) |
| Pacer Model WB 67-250 Hydrant | LV-WM-3 (PDF) |
| Typical Hydrant Lead Detail | LV-WM-4 (PDF) |
| Standard Air Release Manhole (48" Inside Diameter) | LV-WM-5 (PDF) |
| Thrust Blocking Detail | LV-WM-6 (PDF) |
| Typical Watermain Lowering | LV-WM-7 (PDF) |
| Installation of Irrigation System | LV-WM-8 (PDF) |
| Storm Sewer | Plate Number |
|---|---|
| Shallow Catch Basin (Precast Concrete) (24" x 36" Square) | LV-STM-1 (PDF) |
| Catch Basin with Bottom Slab | LV-STM-1A (PDF) |
| Manhole (48" Inside Diameter) | LV-STM-2 (PDF) |
| Street D412 Curb Transition at Catch Basins | LV-STM-3 (PDF) |
| Large Diameter Manhole (Deep Lines) | LV-STM-4 (PDF) |
| Slab-Top Manhole (48" Inside Diameter) | LV-STM-5 (PDF) |
| Trash Guard for Apron | LV-STM-6 (PDF) |
| Hand Place Rip Rap | LV-STM-7 (PDF) |
| Piling and Concrete End Section | LV-STM-8 (PDF) |
| Underdrain Detail | LV-STM-9 (PDF) |
| Street Crossing Underdrain Detail | LV-STM-9A (PDF) |
| Draintile Cleanout | LV-STM-10 (PDF) |
| Typical Draintile Service Connections | LV-STM-11 (PDF) |
| Erosion Control Details | LV-STM-12 (PDF) |
| Concrete Pipe L.R. Bends | LV-STM-13 (PDF) |
| Perforated Concrete Pipe | LV-STM-14 (PDF) |
| Precast 48" Diameter Cap Skinner | LV-STM-15 (PDF) |
| Alternate Skimmer Structure | LV-STM-15A (PDF) |
| Sump Manhole or Catch Basin | LV-STM-16 (PDF) |
| Catch Basin Round 27" Diameter | LV-STM-17 (PDF) |
| Silt Fence | LV-STM-18 (PDF) |
| Erosion Control Blanket Installation | LV-STM-19 (PDF) |
| Bioroll Ditch Check Temporary Sediment Control | LV-STM-20 (PDF) |
| Bioroll Blanket System Ditch Check | LV-STM-21 (PDF) |
| Temporary Down Drain on Fill Slope | LV-STM-22 (PDF) |
| Flotation Silt Curtain Work Area and Still Water | LV-STM-23 (PDF) |
| Rock Weeper and Rock Check Ditch Checks | LV-STM-24 (PDF) |
| Ditch Check Spacing | LV-STM-25 (PDF) |
| Bio-Filtration Basin | LV-STM-26 (PDF) |
| Under-Drain Valve and Valve Box | LV-STM-28 (PDF) |
| Vented Cleanout Assembly | LV-STM-29 (PDF) |
| Infiltration Facility Cross-Section | LV-STM-30 (PDF) |
| Streets & Miscellaneous | Plate Number |
|---|---|
| Integral Driveway Apron with B618 Curb (SF Residential) | LV-ST-1 (PDF) |
| Standard Curb D412 and B618 | LV-ST-2 (PDF) |
| Integral Driveway Apron with D412 Curb (SF Residential) | LV-ST-3 (PDF) |
| Integral Driveway Apron (Commercial/Industrial) and Private Streets | LV-ST-4 (PDF) |
| Typical Mailbox Installation | LV-ST-5 (PDF) |
| Plastic Manhole Step | LV-ST-6 (PDF) |
| Typical Standard Castings | LV-ST-7 (PDF) |
| Typical Residential Street Section | LV-ST-8 (PDF) |
| Conservation Easement Post Detail | LV-ST-9 (PDF) |
| Bituminous Trail Typical Sections | LV-ST-10 (PDF) |
| Public Utility Coordinate Requirements | LV-ST-11 (PDF) |
| Rock Construction Entrance | LV-ST-12 (PDF) |
| By-Pass and Turn Lane Typical Layout | LV-ST-13 (PDF) |
| Step Joint and Bituminous Edge Mill | LV-ST-14 (PDF) |
| Concrete Walk Typical Sections | LV-ST-15 (PDF) |
| Street Name Sign Post Detail | LV-ST-16 (PDF) |
| MnDOT Standard Plates | Plate Number |
|---|---|
| Reinforced Concrete Pipe | 3000K |
| Gasket Joint for Reinforced Concrete Pipe | 3006F |
| Concrete Apron for Reinforced Concrete Pipe | 3100G |
| Concrete Apron for Reinforced Concrete Pipe - Arch | 3110G |
| Concrete Pipe Ties | 3145E |
| Concrete Short Cone and Adjusting Ring | 4010G |
| Manhole or Catch Basin | 4020E |
| Reinforced Concrete Surge Basin | 5200B |
| Pedestrian Curb Ramp | 7036F |
| Concrete Curb and Gutters | 7100F |
| Concrete Curb and Gutter | 7102H |
| Concrete Approach Nose Detail | 7113A |
| Standard Barricades | 8000I1 |
| Breakaway Barricades | 8000I2 |
| Permanent Barricade | 8002F |
| Drainage Manual | Figure Number |
|---|---|
| Classes of Bedding and Imperfect Trench for Embankment Conditions | A5-294.342 |
| Classes of Bedding for Trench Conditions | B5-294-342 |
-
Zach Johnson
City EngineerPhone: 952-985-4501
-
Engineering Division
Physical Address
20195 Holyoke Avenue
Lakeville, MN 55044